<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-24 05-35-49
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 43 dBuV Classic
Pilot RDS Phase Difference
6.6 kHz 2.6 kHz 90 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
14 kHz 34 kHz 6838 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-2,8 dBr 1,10 dBr 2,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Othello usoitto (Dvorak) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 34 kHz MIN: 14 kHz % above 76 kHz: 0,0000 Acquired: 2026/01/24 5.34.45 Total samples: 6838 Equivalent time: 0:05:41 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200